Beam Conversion Tables

Equivalent Glulam Sections For Solid Sawn, Steel, and LVL Beams.

List of connectors and connections.

List of connectors and connection types for glulam beams...

2023 AITC TECHNICAL NOTE 21

The AITC Technical Note 21, titled “Volume Factor for...

Glulam Beams and Columns Designs

QB Corporation Glulam Beams and Columns Designs

Instagram

Equivalent Glulam Sections For Solid Sawn Beams

Sawn Section  Normal Size Roof Beams  Select Structural Roof Beams  No. 1 Floor Beams 
3 x 8 3-1/8 x 6 3-1/8 x 6 3-1/8 x 7-1/2 
3 x 10 3-1/8 x 7-1/2 3-1/8 x 6 3-1/8 x 9 
3 x 12 3-1/8 x 9 3-1/8 x 7-1/2 3-1/8 x 12 
3 x 14 3-1/8 x 10-1/2 3-1/8 x 9 3-1/8 x 13-1/2
4 x 6 3-1/8 x 6 3-1/8 x 6 3-1/8 x 6 
4 x 8 3-1/8 x 6 3-1/8 x 6 3-1/8 x 9 
4 x 10 3-1/8 x 9 3-1/8 x 7-1/2 3-1/8 x 10-1/2
4 x 12 3-1/8 x 10-1/2 3-1/8 x 9 3-1/8 x 12 
4 x 14 3-1/8 x 12 3-1/8 x 10-1/2 3-1/8 x 13-1/2
4 x 16 3-1/8 x 13-1/2 3-1/8 x 12 3-1/8 x 6 
6 x 8 5-1/8 x 7-1/2 5-1/8 x 7-1/2 5-1/8 x 9 
6 x 10 5-1/8 x 9 5-18 x 7-1/2 5-1/8 x 10-1/2
6 x 12 5-1/8 x 10-1/2 5-1/8 x 9 5-1/8 x 12 
6 x 14 5-1/8 x 12 5-1/8 x 10-1/2 5-1/8 x 13-1/2
6 x 16 5-1/8 x 13-1/2 5-1/8 x 12 5-1/8 x 16-1/2
6 x 18 5-1/8 x 15 5-1/8 x 13-1/2 5-1/8 x 18 
6 x 20 5-1/8 x 18 5-1/8 x 16-1/2 5-1/8 x 19-1/2
8 x 10 6-3/4 x 9 6-3/4 x 9 6-3/4 x 10-1/2
8 x 12 6-3/4 x 10-1/2 6-3/4 x 10-1/2 6-3/4 x 12 
8 x 14 6-3/4 x 12 6-3/4 x 12 6-3/4 x 13-1/2
8 x 16 6-3/4 x 13-1/2 6-3/4 x 13-1/2 6-3/4 x 16-1/2
8 x 18 6-3/4 x 16-1/2 6-3/4 x 15 6-3/4 x 18 
8 x 20 6-3/4 x 18 6-3/4 x 16-1/2 6-3/4 x 19-1/2
8 x 22 6-3/4 x 19-1/2 6-3/4 x 18 6-3/4 x 22-1/2

Key Specs of Conversion Charts Above: 

Roof beam sections are compared based on equivalent bending resistance only. These  sizes assume a dry condition of use and a 1.15 increase for the duration of the load (as for snow loading) 

as applicable to wood members, sizes shown should also be checked for shear, deflection, and other applicable strength properties and design considerations. An Fb value of 2400 psi, modified by the AITC volume effect factor, was used to determine glulam roof beam sections.  Floor beam sections are compared based on equivalent stiffness (E1) only, assuming a  dry condition of use for the wood members. Sizes shown should also be checked for shear,  bending, and other applicable strength properties and design considerations. A MOE value of 1,800,000 psi was used to determine glulam floor beam sections.  

Solid-sawn sections are based on the assumption of using either a select structural or No. 1  visual grade having the following assumed design values:  

Members 2 to 4 inches thick and 5 inches wider: 

Select Structural Fb=1450 psi MOE=1,900,000 
No.1 Fb=1000 psiMOE=1,700,000 

Members having a least dimension of 5 inches or greater:

Select structural Fb=1600 psi MOE=1,600,00 
No. 1 Fb=1350 psiMOE=1,600,000 

Equivalent Glulam Sections for Steel Beams:

Steel Section Roof Beams Floor Beams 
W 6 x 9 3-1/8 x 10-1/2 or 5-1/8 x 9 3-1/8 x 10-1/2 or 5-1/8 x 9 
W 8 x 10 3-1/8 x 12 or 5-1/8 x 9 3-1/8 x 13-1/2 or 5-1/8 x 12 
W 12 x 14 3-1/8 x 16-1/2 or 5-1/8 x 13-1/2 3-1/8 x 18 or 5-1/8 x 15 
W 12 x 16 3-1/8 x 18 or 5-a1/8 x 13-1/2 3-1/8 x 19-1/2 or 5-1/8 x16-1/2
W 12 x 19 3-1/8 x 19-1/2 or 5-1/8 x16-1/2 3-1/8 x 21 or 5-1/8 x18 
W 10 x 22 3-1/8 x 21 or 5-1/8 x 16-1/2 3-1/8 x 19-1/2 or 5-1/8 x16-1/2
W 12 x 22 5-1/8 x 18 or 6-3/4 x 15 5-1/8 x 19-1/2 or 6-3/4 x 16-1/2
W 14 x 22 5-1/8 x 18 or 6-3/4 x 16-1/2 5-1/8 x 21 or 6-3/4 x 18 
W 12 x 26 5-1/8 x 19-1/2 or 6-3/4 x 18 5-1/8 x 21 or 6-3/4 x 19-1/2
W 14 x 26 5-1/8 x 21 or 6-3/4 x 18 5-1/8 x 21 or 6-3/4 x 19-1/2
W 16 x 26 5-1/8 x 21 or 6-3/4 x 19-1/2 5-1/8 x 22-1/2 or 6-3/4 x 21 
W 12 x 30 5-1/8 x 21 or 6-3/4 x 19-1/2 5-1/8 x 21 or 6-3/4 x 19-1/2
W 14 x 30 5-1/8 x 22-1/2 or 6-3/4 x 19-1/2 5-1/8 x 22-1/2 or 6-3/4 x 21 
W 16 x 31 5-1/8 x 24 or 6-3/4 x 21 5-1/8 x 25-1/2 or 6-3/4 x 22-1/2
W 14 x 34 5-1/8 x 24 or 6-3/4 x 21 5-1/8 x 24 or 6-3/4 x 22-1/2
W 18 x 35 5-1/8 x 27 or 6-3/4 x 24 5-1/8 x 27 or 6-3/4 x 25-1/2
W 16 x 40 5-1/8 x 28-1/2 or 6-3/4 x 25-1/2 5-1/8 x 27 or 6-3/4 x 25-1/2
W 21 x 44 5-1/8 x 33 or 6-3/4 x 28-1/2 5-1/8 x 33 or 6-3/4 x 30 
W 18 x 50 5-1/8 x 34-1/2 or 6-3/4 x 30 5-1/8 x 31-1/2 or 6-3/4 x 26-1/2
W 21 x 50 5-1/8 x 34-1/2 or 6-3/4 x 31-1/2 5-1/8 x 34-1/2 or 6-3/4 x 31-1/2
W 18 x 55 —————- or 6-3/4 x 31-1/2 ————— or 6-3/4 x 30 
W 21 x 62 —————- or 6-3/4 x 36 ————— or 6-3/4 x 34-1/2

Key Specs of Conversion Charts Above: 

Roof beam sections are compared based on equivalent bending resistance only. These sizes assume a dry condition of use and a 1.15 increase for the duration of the load (as for snow loading)  as applicable to wood members. Sizes shown should also be checked for shear, deflection, and other applicable strength properties and design considerations. An Fb value of 2400 psi, modified by the AITC volume effect factor, was used to determine glulam roof beam sections. 

Floor beam sections are compared based on equivalent stiffness (E1) only, assuming a  dry condition of use for the wood members. Sizes shown should also be checked for shear, bending, and other applicable strength properties and design considerations. A MOE value of 1,800,000 psi was used to determine glulam floor beam sections.  

Steel sections were selected as the most economical from the “Manual of Steel Construction,”  AISC, 8th Edition. Design values used for conversion were: 

Fy=36 ksi Fb=0.66 x FyMOE=29,000 ksi 

Equivalent Glulam Sections for LVL Beams:

LVL Section Roof Beams Floor Beams 
2 pcs. 1-3/4 x9-1/2 3-1/8 x 12 or 5-1/8 x 9 3-1/8 x 10-1/2 or 5-1/8 x 9 
2 pcs. 1-3/4 x 11-7/8 3-1/8 x 15 or 5-1/8 x 12 3-1/8 x 13-1/2 or 5-1/8 x 12 
2 pcs. 1-3/4 x 14 3-1/8 x 16-1/2 or 5-1/8 x 13-1/2 3-1/8 x 16-1/2 or 5-1/8 x 13-1/2
2 pcs. 1-3/4 x 16 3-1/8 x 19-1/2 or 5-1/8 x 15 3-1/8 x 18 or 5-1/8 x 15 
2 pcs. 1-3/4 x 18 3-1/8 x 21 or 5-1/8 x 16-1/2 3-1/8 x 19-1/2 or 5-1/8 x 16-1/2
3 pcs. 1-3/4 x 9-1/2 3-1/8 x 21 or 5-1/8 x 10-1/2 3-1/8 x 12 or 5-1/8 x 10-1/2
3 pcs. 1-3/4 x 11-7/8 5-1/8 x 18 or 5-1/8 x 13-1/2 3-1/8 x 15 or 5-1/8 x 13-1/2
3 pcs. 1-3/4 x 14 5-1/8 x 18 or 6-3/4 x 16-1/2 3-1/8 x 18 or 5-1/8 x 15 
3 pcs. 1-3/4 x 16 5-1/8 x 19-1/2 or 6-3/4 x 16-1/2 5-1/8 x 18 or 5-1/8 x 18 
3 pcs. 1-3/4 x 18 5-1/8 x 21 or 6-3/4 x 18 5-1/8 x 19-1/2 or 6-3/4 x 18 

Key Specs of Conversion Charts Above: 

Roof beam sections are compared based on equivalent bending resistance only. These sizes assume a dry condition of use and a 1.15 increase for duration of the load (as for snow loading)  as applicable to wood members. Sizes shown should also be checked for shear, deflection, and other applicable strength properties and design considerations. For determining glulam roof beam sections, an Fb value of 2400 psi was modified by the AITC volume effect factor. 

Floor beam sections are compared based on equivalent stiffness (E1) only, assuming a  dry condition of use for the wood members. Sizes shown should also be checked for shear,  bending, and other applicable strength properties and design considerations. A MOE value of 1,800,000 psi was used to determine glulam floor beam sections.  

LVL sections are based on the following assumed design values: 

Fb=3200 psi (adjusted for Cy=(12/d)1/6 for  depths greater than 12 inches.) MOE=2,000,000 PSI 

Custom Beams

We at QB take pride in providing quality custom beams, meeting each of the specifications provided by our customers. Within our facility, we can manufacture...

Stock Beams

QB stocks various standard-sized beams (3.125”, 5.125”, and 6.75”) for quicker shipments and deliveries to your job site. The laminated beams..

Utility Structures

The rising demand for alternative energy sources, such as wind and solar facilities, has resulted in an increased need for wood utility poles and framing...

Wood Pellets

QB Corporation is committed to increasing efficiency in our use of wood resources. Our LEMHI VALLEY WOOD PELLETS are manufactured using by-products...